Best Solar Generator for a Well Pump

Most well pumps are 240V, so most solar generators cannot run them. We cover the units that can, the honest 240V rule, and how to size for a deep well.

Disclosure: Some links in this article are affiliate links. We may earn a small commission if you make a purchase, at no extra cost to you. As an Amazon Associate I earn from qualifying purchases. Full disclosure.
On this page · 11 sections

Research-based comparisons. How we choose products.

Most deep-well pumps run on 240 volts. Most power stations put out only 120 volts, and a 120V station cannot turn a 240V pump at all, however big its battery. So check your pump’s voltage first. It is on the nameplate in the pressure switch box or control box, or in your well driller’s report.

  • 230V or 240V: you need one of the two 240V units below.
  • 115V or 120V: one of the two 120V units can work, if its surge covers your pump’s start.

Then size for the start, not the run. A pump pulls several times its running power for a moment as it kicks on. Each pick says which pumps its surge covers on paper, using Franklin Electric’s motor data.

EcoFlow DELTA Pro 3

EcoFlow

High-end
Lightest 240V unit

Best for: 1/2 HP or 3/4 HP 3-wire, 240V

Anker SOLIX F3800 Plus

Anker

High-end
Most 240V output

Best for: 240V, most running power

EcoFlow DELTA Pro

EcoFlow

Premium
For 120V pumps

Best for: 120V pumps, bigger battery

EcoFlow DELTA 3 Max Plus (2048Wh)

EcoFlow

Premium
Lighter 120V pick

Best for: 1/2 HP 115V 3-wire

Heads Up

A 120-volt power station cannot run a 240-volt well pump, no matter how big its battery is. This is the most common and most expensive mistake. If your pump’s nameplate says 230V or 240V, you need one of the 240V units here: the DELTA Pro 3 or SOLIX F3800 Plus. If it says 115V or 120V, a large 120V station may run it, once you check the pump’s locked-rotor amps against the station’s surge rating. Above-ground jet pumps are often dual voltage, so check how yours is wired.

Sizing: Why You Buy for the Surge, Not the Run

A pump motor pulls a big spike of current the instant it starts, far more than it draws while running. If a station cannot cover that spike, it trips the moment the pump kicks on, even if it looked big enough on paper. So you size for the start.

The number to find is the pump’s locked-rotor amps (LRA). It is printed on the motor or control-box label, or in the pump manual. LRA times the motor’s rated voltage gives its worst-case starting demand. For reference, Franklin Electric’s motor data for common 4-inch submersible motors:

  • 1/2 HP: about 960 watts at maximum load. It starts at about 5,300 VA (230V 3-wire), 5,800 VA (115V 3-wire) or 7,400 VA (2-wire, either voltage).
  • 3/4 HP (230V): about 1,310 watts at maximum load. It starts at about 7,900 VA (3-wire) or 9,400 VA (2-wire).
  • 1 HP (230V): about 1,600 watts at maximum load. It starts at about 9,600 VA (3-wire) or 11,200 VA (2-wire).
  • 1.5 HP (230V): about 2,100 to 2,300 watts at maximum load. It starts at about 11,800 VA (3-wire) or 15,200 VA (2-wire).

Two-wire pumps have their starting parts inside the motor and no control box, so they are harder to start than three-wire pumps. Real starting draw falls when the voltage dips, so a station rated a bit below these figures may still start some pumps. But makers rarely say how long their surge rating lasts.

To get your own pump’s number, read its start with an inrush clamp meter on the pump circuit, or have an electrician do it.

Our pick Mid-range

Klein Tools CL445 HVAC Clamp Meter

Klein Tools

Its inrush mode reads your pump's real starting current as the pump kicks on. That is the number to give the station maker before you buy. Skip it if an electrician or pump installer will take the reading for you. Opening a pump control box is live electrical work, so if that is not for you, have a pro measure it. It is a full HVAC meter, with extras like a temperature probe you may never use.

Check Price on Amazon

The practical takeaway: compare your pump’s LRA times its voltage with the station’s surge rating. Then give the station’s maker your pump’s voltage, horsepower, LRA and whether it is 2-wire or 3-wire, and ask whether their unit will start it. Soft-start pumps such as Grundfos SQ models, and constant-pressure drives such as Franklin’s SubDrive, reduce the starting surge; both need a qualified installer. If your pump has neither, an add-on soft starter can lower its start. A small power station will run your lights and fridge but will usually stall a well pump.

EcoFlow DELTA Pro 3

If your 240V pump is 1/2 HP, or a 3/4 HP 3-wire, the DELTA Pro 3 is the lightest way here to get 240V from one box. It has an L14-30 outlet (120V/240V) and a NEMA 6-20 outlet (240V), so it needs no hub and no second unit. Its 8000-watt surge covers Franklin’s start figures for a 1/2 HP 240V pump and a 3/4 HP 3-wire on paper.

EcoFlow says it can power a 1 HP water pump, but it does not say what kind. Franklin’s 1 HP submersible starts at about 9,600 VA or more, above its 8,000W surge on paper, so give EcoFlow your pump’s LRA before you buy. Skip it if your pump is a 3/4 HP 2-wire, or 1 HP or larger, with no soft start.

The battery is 4096Wh with 4000 watts continuous. It expands to 12kWh per unit with extra batteries and recharges from solar during the day. The downsides are weight and how the outlets switch. At about 114 pounds it needs a fixed spot near the pump circuit, and its 120V outlets turn off while its 240V outlets are on.

Lightest 240V unit

EcoFlow DELTA Pro 3

EcoFlow

High-end

  • 240V from one unit, via its L14-30 or NEMA 6-20 outlet
  • 4096Wh battery, 4000W output, 8000W surge
  • Expandable to 12kWh per unit
  • Pairs with solar for daytime recharging
  • Heavy at about 114 lbs
  • High-end price
  • 120V outlets turn off while 240V is on

Best for: 1/2 HP and 3/4 HP 3-wire 240V pumps

Pro Tip

You almost never need to run a well pump continuously. Run it for 20 to 30 minutes to refill your pressure tank and fill every barrel, jug, and the bathtub, then shut it off. The stored water carries you for hours, and you only fire the pump back up when you run low. This stretches battery runtime a long way, so a smaller battery can do the job. The full strategy is in our well pump backup power guide.

Anker SOLIX F3800 Plus

The SOLIX F3800 Plus is the current version of Anker’s F3800. It gives 240V from one unit through an L14-30 outlet, and Anker lists 6000 watts of output, the most of any pick here. That is room to run the pump with a fridge and lights, as long as their starts do not overlap.

The catch is the start. Anker’s page lists no surge rating for the Plus, so you cannot check it against your pump on paper. Before you buy, give Anker your pump’s voltage, horsepower, LRA and whether it is 2-wire or 3-wire, and ask them to confirm it will start. Skip it if you want a published surge figure to compare; the DELTA Pro 3 lists one.

The battery is 3840Wh and expands to about 27kWh with extra batteries. It takes up to 3200 watts of solar. Anker notes that the 240V output cannot be used while the unit is charging from 120V AC. The trade-off is size: at about 137 pounds it is bulky and wants a dedicated spot.

Most 240V output

Anker SOLIX F3800 Plus

Anker

High-end

  • 240V from one unit, via its L14-30 outlet
  • 6000W output, the most here
  • 3840Wh, expandable to about 27kWh
  • Takes up to 3200W of solar
  • Very heavy at about 137 lbs
  • Anker lists no surge rating for this model
  • No 240V while charging from a 120V outlet

Best for: 240V pumps that need the most running power

EcoFlow DELTA Pro (Original)

The original DELTA Pro is for a 120V pump. Its 7200-watt surge covers Franklin’s 1/2 HP 115V 3-wire start, about 5,800 VA, with room on paper. A 2-wire, about 7,400 VA, is just above it. Its 3600Wh battery runs more fill-the-tank cycles than the DELTA 3 Max Plus. Check your pump’s locked-rotor amps first, and skip it if your pump is 240V: one unit has no 240V outlet.

It is also an on-ramp to 240V. Two DELTA Pros bonded through EcoFlow’s Double Voltage Hub give 240 volts, so you can start with one unit for general backup and add the second unit plus the hub later. Each unit expands to about 10.8kWh with two extra batteries.

Be clear about the 240V part, though. That path means two large DELTA Pros plus the hub, at about 99 pounds each. If your only goal is to run a 240V well today, the DELTA Pro 3 or SOLIX F3800 Plus is the simpler route.

For 120V pumps

EcoFlow DELTA Pro

EcoFlow

Premium

  • 3600Wh battery, 3600W output, 7200W surge
  • Covers a 1/2 HP 115V 3-wire start on paper
  • Expandable to about 10.8kWh per unit
  • Can pair with a second unit for 240V later
  • 120V only from one unit
  • 240V path needs two units plus the hub
  • Heavy at about 99 lbs

Best for: 120V pumps, with a bigger battery

EcoFlow DELTA 3 Max Plus

The DELTA 3 Max Plus is the lighter 120V pick, for a 1/2 HP pump. Its 6000-watt surge covers Franklin’s 1/2 HP 115V 3-wire start, about 5,800 VA, on paper, per EcoFlow’s specs. A 2-wire, about 7,400 VA, is above both 120V stations here on paper, so add the soft starter below or ask the maker. For a jet pump or a bigger 120V pump, check its LRA times its nameplate voltage against the DELTA Pro’s 7,200W.

At about 49 pounds it weighs about half as much as the DELTA Pro. The trade-off is a 2048Wh battery, also about half the DELTA Pro’s, so plan on short fill-the-tank runs. It has 120V outlets only, so skip it if your pump is 240V.

Lighter 120V pick

EcoFlow DELTA 3 Max Plus (2048Wh)

EcoFlow

Premium

  • 2048Wh, 3000W continuous, 6000W surge
  • About 49 lbs, half the DELTA Pro's weight
  • Expandable from 2 to 10kWh
  • 120V only, no 240V outlet
  • Smaller battery, shorter fill-the-tank runs

Best for: 1/2 HP 115V 3-wire pumps

If Your Pump’s Start Is Too Big for One Unit

If your pump’s start is above the surge of the station you want, a soft starter can lower it. The maker’s sizing sheet works its example at about a 40% cut in starting current, which may let a smaller station start the pump.

Our pick Mid-range

SoftStart Water Well Pump Soft Starter

SoftStartUSA

Lowers your pump's starting current, about 40% in the maker's worked example, so a smaller station may start it. Skip it if your pump already has a soft start or a constant-pressure drive, such as Grundfos SQ or Franklin SubDrive. A licensed electrician or pump installer wires it into the pump circuit. Its sizing sheet is written for gas generators, so ask SoftStart and your station's maker whether it suits your pump and unit.

Check Price on Amazon

Connecting a Station to Your Well

A licensed electrician installs an inlet box and a transfer switch or interlock that matches your station’s 240V outlet, which is listed on each card above. Never backfeed a wall outlet. Backfeeding can electrocute line workers and start fires.

What We Looked For

  • Voltage match. Whether a unit can run a 240V pump at all. Each card names its 240V outlet, or says it is 120V only.
  • Surge. Each pick’s surge is checked against Franklin Electric’s start figures. The EcoFlow picks list 6,000 watts of surge or more; Anker lists none for the F3800 Plus, so ask Anker. No surge rating guarantees a pump will start.
  • Battery and expansion. A bigger battery means more fill-the-tank cycles in a long outage. Each unit expands and recharges from solar.
  • Weight and setup. These units live in one spot near the pump circuit, and an electrician connects them.

Before You Buy

A solar generator is one piece of a well backup plan. The strategy around it matters as much as the unit:

Frequently Asked Questions

Can a solar generator run a well pump?
Yes, but only the right one. Most deep-well pumps are 240 volt, and most power stations are 120 volt, which cannot run them. Stations that give 240 volts from one unit, like the EcoFlow DELTA Pro 3 or Anker SOLIX F3800 Plus, can power a 240V pump through an electrician-installed inlet and transfer switch. A large 120V unit may run a 120V pump if its surge rating covers the pump's start. Check your pump's voltage first.
How big of an inverter do I need to run a well pump?
Size for the startup surge, not the running load. Find the pump's locked-rotor amps (LRA) on the motor or control-box label; LRA times the motor's voltage is the worst-case starting demand. Franklin Electric's motor data puts common 1/2 HP submersibles at roughly 5,300 to 7,400 VA to start and 1 HP models at roughly 9,600 to 11,200 VA, though actual draw falls as voltage dips. Compare your pump's LRA times its voltage with the station's surge rating, and confirm with the station's maker.
Will a 7,200W, 5,040Wh solar generator run a 240V 1.5 HP well pump?
Only if it has a 240V outlet and its surge rating covers the pump's start. Running is the easy part: a 1.5 HP pump draws about 2,100 to 2,300 watts at full load, well under 7,200W. Starting is the hard part. Franklin Electric's data puts a 1.5 HP, 230V 3-wire motor at 51.4 locked-rotor amps, about 11,800 VA to start, and a 2-wire at 66.2 amps, about 15,200 VA. The EcoFlow DELTA Pro 3 falls short of both on paper with an 8,000W surge, and Anker lists no surge rating for the SOLIX F3800 Plus. A soft starter can cut the start, about 40% in its maker's worked example, which may bring it within reach. Give the soft starter's maker and the station's maker your pump's LRA and whether it is 2-wire or 3-wire, and ask them to confirm.
Why can't my big power station run my well pump?
Almost always because the pump is 240 volt and the power station outputs 120 volt. Battery size has nothing to do with it. A 120V source cannot turn a 240V motor at all. The second possibility is that the unit's surge rating is below the pump's startup spike, so it trips the instant the pump kicks on. Confirm both the voltage and the surge rating against your pump.
Do I need solar panels, or just the battery?
For a short outage, the battery alone is fine. Run the pump in short bursts to fill your pressure tank and storage containers, then shut it off, and a single charge lasts a long time. For a multi-day outage, adding a solar panel lets the unit recharge during the day so you are not limited to one battery's worth of pumping. All the units here accept solar input. To size the panels, see what size power station do I need.
Is a solar generator better than a gas generator for a well?
Each has a place. A gas generator runs as long as you have fuel. A battery station is quiet, works indoors, makes no exhaust and can recharge from solar. Either way, a 240V pump needs a 240V source and a transfer switch or interlock installed by a licensed electrician.

Bottom Line

If your 240V pump is 1/2 HP or a 3/4 HP 3-wire, the EcoFlow DELTA Pro 3 is the lightest way to get 240V from one box. For a 3/4 HP 2-wire, or any pump 1 HP and up, it does not cover the start on paper. The Anker SOLIX F3800 Plus gives the most running power, but Anker lists no surge rating for it, so have Anker confirm it will start your pump.

For a 1/2 HP 115V 3-wire pump, the EcoFlow DELTA Pro gives you the bigger battery and the EcoFlow DELTA 3 Max Plus the lighter box. If your pump starts above the station you want, look at the soft starter or ask the station maker. Whatever you buy, confirm your pump’s voltage off the nameplate first. That tells you which group of picks fits. Then match the surge to your pump’s start.

Certain content that appears on this site comes from Amazon. This content is provided "as is" and is subject to change or removal at any time.